UltraFlex™ Copper Beryllium (CuBe) Mesh
UltraFlex™ combines the optimum mechanical properties of copper beryllium with shielding effectiveness as much as 20 dB higher than conventional materials. It offers superb resiliency for consistent, point-to-point contact requiring the lowest compression forces among all other shielding materials and configurations. A wide range of platings, sizes, configurations and excellent flexibility create optimum design latitude.
| All dimensions shown in inches (millimeters) unless otherwise specified |
|
| Product Highlights | • Hollow knit design eliminates the need for potentially moisture-absorbant core • High cycle life for high traffic applications with no resulting compression set • 100% recovery at 75% deflection • Compression force 80% less than conventional mesh gasket |
| SHIELDING EFFECTIVENESS Transfer Impedance (500 MHz) |
85 - 100 dB |
| H-field (200 KHz) Mil 285 | 60 - 65 dB |
| Plane Wave (2 GHz) Mil 285 | 80 - 115 dB |
| Surface Resistivity | 0.006 - 0.040 ohm/cm2 |
| Volume Resistivity | N/A |
| Available Size Range | 0.060 - 0.500 (1,52 - 12,7) Height |
| Deflection Operating Range | 25 - 75% Deflection |
| Compression Force (based on shape selection) |
From 5 - 25 Lbs./ft. (7,4 - 37Kg/m) @ 30% Deflection - hollow core round |
| Compression Set | 0% @ 75% Compression |
| Joint Unevenness Accommodation | 0.030 - 0.400 (0,76 - 10,16) |
| Compound/Material Availability | CuBe, aluminum, stainless steel wire in various diameters, single or multi strand construction. |
| Temperature Range | Continuous operation @ 250°F (121°C) |
| Available Profiles | Round, "D" shape, round with fin, double round with fin |
| Mounting Methods | Groove, pressure sensitive adhesive, mechanical fasteners, channel mount |
| Custom Shapes Available | Cut to length, diameters other than standard, D-shapes and fin other than standard |
| Fluid Seal | N/A |
| Air/Dust | N/A |
| Galvanic Compatibility | Variety of platings to ensure galvanic compatibility with mating surfaces |
|
Typical Applications for Shielding Gaskets |
• High traffic door opening/closing with minimum compression set • Thin sheet metal doors with minimum latch points • Low compression force for applications that include backplanes, computer chasis, and access covers requiring superb resiliency |